Learn how vinyl siding wind ratings work for Illinois projects, including the difference between advertised wind speed and design pressure measured in pounds per square foot. This contractor guide references VSI practices, ASTM D3679, ASTM D5206, Gentek specifications, and technical support from Brian “JR” Girskis, President of Suburban Wholesale & Supply and a local VSI Trainer.

Illinois Contractor Technical Guide
Wind Ratings Explained for Illinois Contractors
A siding brochure may advertise performance at a certain wind speed, but Illinois contractors need more than a large miles-per-hour number. The more useful specification is the exact product and profile’s wind-load design pressure, measured in pounds per square foot, for the proposed installation.
Contractors working in Moline, Rock Island, East Moline, Silvis, Milan, Coal Valley, and other Illinois communities regularly install siding on homes exposed to thunderstorms, straight-line winds, changing pressure, and windborne debris.
Wind performance is often oversimplified during the sales process. Homeowners hear that one panel is “rated for 150 mph” while another is advertised at an even higher speed. Those numbers may be based on valid testing, but they should not be treated as universal guarantees.
The exact product profile, laboratory setup, building height, site exposure, wall location, effective wind area, substrate, fasteners, spacing, and installation method all affect the real specification. Contractors should sell the complete system—not just the largest number printed in the brochure.
Wind Speed Is Not the Same as Design Pressure
Wind speed is expressed in miles per hour. Design pressure is expressed in pounds per square foot, commonly abbreviated as psf. Design pressure describes the force the installed product is evaluated to resist under specified conditions.
A published wind speed can provide a convenient approximation for marketing and general comparison. Design pressure is the more useful technical value because the required pressure changes with the building and its location.
Two houses in the same Illinois county may not have identical cladding requirements. One may be a single-story home surrounded by nearby buildings, while the other is a taller home on an open rural site with greater wind exposure.
Important Wind-Rating Terms
| Term | What It Means |
|---|---|
| Wind Speed | A measure in miles per hour used by building codes, weather reporting, and product marketing. It does not describe the entire building condition by itself. |
| Design Pressure | The wind pressure a product is designed or tested to resist, normally expressed in pounds per square foot. |
| Negative Pressure | Suction that attempts to pull cladding away from the wall. ASTM D5206 is used to evaluate negative wind-load resistance of rigid plastic siding. |
| Positive Pressure | Pressure pushing toward the wall. The structural sheathing and wall assembly must resist the applicable loads. |
| Exposure Category | A classification related to surrounding terrain and obstructions. Open terrain can create different loads than a densely developed area. |
| Effective Wind Area | The area used when determining the pressure acting on a component or cladding section. |
| Wall Zone | The location on the elevation. Corners and edges can experience higher suction than central wall areas. |
Why Pounds Per Square Foot Matters
Design pressure describes how force is distributed across the wall surface. For example, a rating of 30 psf means the product is rated for 30 pounds of pressure across each square foot under the conditions used to establish that rating.
The total force can become substantial when pressure acts across a large elevation. More importantly, suction is not always uniform. Corners, roof edges, upper stories, and exposed elevations may experience greater demands.
This is why converting a design-pressure rating into a single advertised wind speed can be misleading. The conversion assumes specific building, terrain, wall-zone, height, and effective-area conditions that may not match the actual project.
What Determines the Required Wind-Load Rating?
Local Code Requirements
Illinois communities can adopt and amend building codes locally. Contractors should verify the code edition and requirements enforced by the authority having jurisdiction.
Building Height
Taller walls and upper stories can be exposed to different wind pressures than lower, protected portions of the building.
Terrain and Exposure
Open fields, large bodies of water, sparse development, and elevated sites can create different exposure than dense neighborhoods.
Building Shape
Wall dimensions, roof design, corners, projections, and orientation influence how pressure moves around the structure.
Wall Location
Corner zones can experience stronger suction than the field or center of the wall.
Product and Profile
Double 4-inch, Double 5-inch, Dutch lap, clapboard, board and batten, and other profiles may not share the same design-pressure rating.
VSI Certification and ASTM Standards
The VSI Product Certification Program, now administered through the Polymeric Exterior Products Association, uses independent third-party verification to confirm that listed products comply with applicable ASTM requirements.
ASTM D3679
ASTM D3679 is the standard specification for rigid PVC siding. It addresses product requirements that include weatherability, wind-load resistance, impact resistance, expansion and shrinkage, surface distortion, dimensions, and other characteristics.
ASTM D5206
ASTM D5206 provides test methods for determining negative wind-load resistance of rigid plastic siding. The test applies controlled pressure to an installed specimen to evaluate system performance.
ASTM D4756
ASTM D4756 addresses installation practices for rigid PVC siding and soffit. Product selection and correct installation must work together for the siding to achieve its rated performance.
Certification establishes a credible minimum level of product evaluation. It does not mean every certified panel has the same wind-load rating or can be installed with the same fastening schedule.
How ASTM D5206 Wind Testing Works
In a controlled test, the siding is installed over a specified wall assembly using identified fasteners, spacing, accessories, and attachment conditions. Negative pressure is then applied to simulate suction pulling the cladding away from the wall.
The result belongs to the tested assembly and is translated into a design-pressure rating according to the applicable certification requirements. Changing the panel, profile, fastener, spacing, starter strip, sheathing, or installation method may change the system’s performance.
Contractors should never assume that a result for one Gentek profile automatically applies to every Gentek siding profile.
What Does Gentek’s “Up to 253 MPH” Claim Mean?
Gentek literature states that certain Sequoia Select configurations withstood laboratory wind-load testing equivalent to speeds up to 253 mph. The same literature notes that wind-load performance can vary by profile design.
This is evidence of strong tested performance for specified product configurations. It is not a guarantee that every Sequoia Select profile, wall, fastener schedule, or real-world installation will withstand a 253-mph storm.
Before using the claim in a proposal, confirm:
- The exact product and profile represented by the test.
- The published design-pressure rating.
- The fastener type, spacing, and penetration used.
- The substrate and sheathing conditions.
- The assumptions used to translate pressure into wind speed.
- Whether the proposed field installation matches the rated assembly.
Why Sequoia Select Is a Strong Wind-Focused Option
Sequoia Select is more than a thicker panel. Gentek combines several features intended to strengthen the complete siding system.
.046-Inch Nominal Thickness
The heavy-duty wall thickness increases rigidity and helps produce straighter, smoother-looking walls.
Full-Roll Nailing Hem
The reinforced hem is designed to provide stronger wall attachment than a basic single-layer hem.
Advantage Lock System
The engineered lock connects adjoining courses and supports panel stability.
ASTM D5206 Testing
Sequoia Select has been tested for negative wind-load resistance under the industry-recognized test method.
Thickness contributes to performance, but it is not the entire wind story. The nailing hem, lock, profile geometry, fasteners, wall support, and installation method work as a system.
Installation Controls Whether the Rating Means Anything
A high-rated siding panel can underperform when installed incorrectly. Wind-load testing assumes the product is attached according to the tested or specified method.
Critical wind-performance details include:
- Use the exact fastener type, length, shank, and head diameter specified by the manufacturer.
- Maintain the required fastener spacing for the product and wind condition.
- Achieve the required penetration into approved nailable material.
- Center fasteners in applicable nailing slots.
- Do not drive fasteners tightly against the vinyl nailing hem.
- Fully engage each panel lock without stretching the siding upward.
- Use a starter strip compatible with the siding’s lock design.
- Keep starter strips level, secure, and continuous where required.
- Verify sheathing and substrate condition before covering the wall.
- Follow enhanced fastening instructions when project conditions require them.
Tighter Nailing Does Not Mean Better Wind Resistance
Vinyl siding must remain free to expand and contract. Driving fasteners tightly against the nailing hem can restrict movement and contribute to buckling or distortion.
Strong wind performance comes from correct fastener placement, penetration, spacing, head diameter, panel engagement, and attachment to sound nailable material—not from pinning the siding tightly to the wall.
Contractors should follow the current Gentek instructions and project-specific requirements rather than improvising a “tighter must be stronger” fastening method.
Why Wall Corners Deserve More Attention
Wind accelerates and changes direction as it moves around a building. Wall corners can experience higher suction than the central field of an elevation.
A product that meets the pressure requirement in the center of the wall still needs to be evaluated for the project’s more demanding corner zones. This is one reason a single wind-speed claim cannot replace a project-specific design-pressure check.
Contractors should also examine outside corner posts, J-channels, starter strips, soffit, fascia, and other accessories. The main siding panel is only one component of the exterior system.
Do Not Ignore Soffit and Accessories
Strong wind can enter through a failed soffit or detached accessory and place additional pressure on the building assembly. High-wind projects may require soffit products with an appropriate design-pressure rating and specific support or fastening.
Siding, soffit, starter strips, corners, trim, fascia, and flashing should be selected and installed as a compatible system. A strong wall panel does not compensate for an improperly supported soffit or mismatched starter strip.
Installing Vinyl Siding Over Foam Sheathing
Energy-code assemblies increasingly include continuous foam sheathing. Contractors cannot assume the same fastening approach used over wood-based structural sheathing will automatically apply.
The siding fasteners may need to pass through the foam and penetrate approved nailable material by the required amount. Foam thickness, structural sheathing, framing location, fastener length, and manufacturer instructions must all be considered.
Both the siding’s wind-load rating and the wall assembly must be properly specified. When the prescriptive requirements are unclear, consult the manufacturer, local building official, design professional, or applicable code-compliance documentation.
Wind-Rating Checklist for Illinois Contractors
-
1
Identify the adopted code and local amendments for the project jurisdiction.
-
2
Determine the required design pressure for the building and wall zones.
-
3
Select the exact manufacturer, product line, and profile.
-
4
Obtain the product certification listing and published design-pressure rating.
-
5
Verify the approved sheathing, substrate, fasteners, spacing, and penetration.
-
6
Confirm compatible starter strips, corner posts, channels, soffit, and accessories.
-
7
Train the crew on the project-specific installation requirements.
-
8
Document product labels, cartons, installation details, and completed elevations.
Common Wind-Rating Mistakes
- Quoting only the brochure’s mph number: This ignores the design pressure and the assumptions used to convert pressure into an approximate speed.
- Assuming every profile has the same rating: Wind-load performance can vary by panel and profile design.
- Using whatever fastener is already on the truck: Fastener head size, length, penetration, corrosion resistance, and spacing can affect performance.
- Nailing tightly: Vinyl must remain free to move with temperature changes.
- Ignoring the starter strip: An incompatible or poorly attached starter strip can allow the bottom course to disengage.
- Ignoring soffit: Soffit and accessories may require their own support, rating, and installation details.
- Assuming local requirements are identical statewide: Verify the code and amendments enforced by the Illinois jurisdiction responsible for the project.
Local Contractor Training and Technical Support
Leverage Your VSI Trainer: Brian “JR” Girskis
Brian “JR” Girskis, President of Suburban Wholesale & Supply, is a VSI Trainer with more than 25 years of experience in building materials and exterior remodeling.
JR can help Illinois contractors interpret product information, compare profiles, locate design-pressure ratings, review fastening practices, address expansion clearances, identify compatible accessories, and connect manufacturer specifications with real installation conditions.
This support is especially useful when crews move from basic vinyl siding into premium .046-inch panels, extended-length products, vertical siding, specialty profiles, insulated systems, or projects with greater wind exposure.
Our Practical Recommendation
Use advertised wind speed as a starting point—not the final specification. Determine the project’s required design pressure and compare it with the rating for the exact siding profile and installation method.
Gentek Sequoia Select is a strong premium option because it combines a .046-inch nominal panel, full-roll nailing hem, Advantage Lock system, ASTM D3679 certification, and negative wind-load testing under ASTM D5206.
The rating only has value when the product is correctly selected and the field installation follows the specified substrate, fastener, spacing, penetration, starter-strip, lock-engagement, and accessory requirements.
Get Wind-Rating Support Before You Order
Bring your plans, elevations, specifications, product questions, or project conditions to Suburban Wholesale & Supply. Our team can help Illinois contractors compare Gentek products, locate technical literature, review accessories, assemble material orders, and coordinate jobsite delivery.
We support contractors throughout Moline, Rock Island, East Moline, Silvis, Milan, Coal Valley, and the surrounding Quad Cities.
Brian “JR” Girskis, President and VSI Trainer
Suburban Wholesale & Supply
3602 North Harrison Street
Davenport, Iowa
This article provides general product and installation information. It is not a project-specific wind design or engineering determination. Codes, product specifications, certification listings, and installation instructions may change. Verify the exact profile, current design-pressure rating, wall assembly, local code, manufacturer requirements, and any necessary professional design before installation.
Contractor Notes
We‘re here to help.
Suburban Wholesale & Supply works with contractors, remodelers, builders, and property professionals across Davenport, Bettendorf, Moline, Rock Island, and the wider Quad Cities. If Vinyl Siding Wind Ratings Explained for Illinois Contractors affects a project you are pricing, our team can help compare product lines, confirm available options, and prepare a quote that fits the opening, exterior, or jobsite requirements.
Our counter and showroom teams support window, patio door, entry door, storm door, siding, trim coil, gutter protection, and accessory orders every week. We can talk through manufacturer differences, color and finish selections, installation details, lead times, and documentation so you can give your customer clear answers before the work begins.
For current availability, contractor pricing, product literature, or help matching this topic to a real project, contact Suburban Wholesale & Supply or send the details through our quote form. We will help you move from product research to an accurate material order with fewer surprises.
Share This Post
Share it on Facebook or X, or send it through your device share sheet for Instagram.